CDHD Variables and Commands
VarCom Reference Manual 355
SININITMODE
Definition Sine/Cosine Calibration Mode
Type Variable (R/W)
Description Enables/disables the automatic calibration of the resolver
sine/cosine signals at power up.
Syntax Read: SININITMODE
Write: SININITMODE <value>
Firmware 1.0.6
Drive status Enabled | Disabled
Range 0 = Automatic calibration of resolver disabled
1 = Automatic calibration of resolver enabled
Default value 0
Unit Not Applicable
Non-volatile Yes
See also FEEDBACKTYPE
RESBW
SININITST
SINPARAM
CANopen 20BFh, sub-index 0