UNITSLINPOS
Definition Units Linear Position
Type Variable (R/W)
Description Gets/sets a value that defines the units of position variables
in a linear system.
Syntax Read: UNITSLINPOS
Write: UNITSLINPOS <value>
Firmware 1.0.6
Drive status Enabled | Disabled
Range 0 = pitch (motor cycles)
1 = count (pulses per revolution - PPR lines)
3 = mm
4 = user
Default value 1
Unit Not Applicable
Non-volatile Yes
See also MOTORTYPE