THERMODE
Definition Motor Over-Temperature Mode
Type Variable (R/W)
Description Gets/sets a value that defines how the drive will respond to
an over-temperature fault.
Syntax Read: THERMODE
Write: THERMODE <value>
Firmware 1.0.6
Drive status Enabled | Disabled
Range 0 = Disable drive immediately.
3 = Ignore thermostat input.
4 = Issue warning only.
5 = Issue warning; if condition persists after THERMTIME,
issue fault.
Default value 0
Unit Not Applicable
Non-volatile Yes
See also THERM
THERMCLEARLEVEL
THERMREADOUT
THERMTIME
THERMTRIPLEVEL
THERMTYPE
CANopen 20C6h, sub-index 0