EasyManua.ls Logo

Servotronix CDHD - Uvmode

Servotronix CDHD
416 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CDHD Variables and Commands
VarCom Reference Manual 391
UVMODE
Definition Under-Voltage Mode
Type Variable (R/W)
Description Gets/sets a value that defines how the drive will respond to
an under-voltage fault.
Syntax Read: UVMODE
Write: UVMODE <value>
Firmware 1.0.6
Drive status Enabled | Disabled
Range 0 = Latches fault immediately.
1 = Shows warning only (when disabled, does not display
warning).
2 = Shows warning, then waits UVTIME before the fault is
latched (when disabled, does not display warning).
3 = Fault only if under-voltage exists and drive is enabled.
Default value 0
Unit Not Applicable
Non-volatile Yes
See also UVRECOVER
UVTHRESH
UVTIME
VBUS
VBUSREADOUT
CANopen 20CDh, sub-index 0