ESTMOTORPARAM
Definition Motor Winding Estimation
Type Command
Description Executes a procedure that automatically measures motor
winding properties. Line to line inductance and resistance
are measured and reported in the status completion
message. The variables ML and MR are not altered by the
procedure.
Before issuing the ESTOMOTORPARAM command, the drive
must be successfully configured (CONFIG), disabled, and
ready to be enabled.
After issuing the ESTOMOTORPARAM command, enable the
drive to start the procedure.
The drive 7-segment display shows At3 while the procedure
is running.
Syntax ESTMOTORPARAM
Firmware 1.3.2
Drive status Disabled
Range Not Applicable
Default value Not Applicable
Unit Not Applicable
Non-volatile Not Applicable
See also ESTMOTORPARAMST