CDHD Variables and Commands
VarCom Reference Manual 325
PHASEFINDTIME
Definition Time of Phase Finding Mechanism
Type Variable (R/W)
Description Gets/set the duration of the phase finding mechanism.
Syntax Read: PHASEFINDTIME
Write: PHASEFINDTIME <value>
Firmware 1.0.6
Drive status Disabled
Range 0 to 10000
Default value 100
Unit ms
Non-volatile Yes
See also PHASEFIND
PHASEFINDMODE
CANopen 20AAh, sub-index 0