CDHD Variables and Commands
VarCom Reference Manual 153
ILIMACT
Definition Drive Actual Current Limit
Type Variable (R)
Description Reports the actual current limit. Useful when the limit is
dynamic due to analog control over current limit.
ILIMACT is the minimum between ILIM and the analog
current limit (only for ANIN2MODE 2).
Syntax ILIMACT
Firmware 1.0.6
Drive status Enabled | Disabled
Range Not Applicable
Default value Not Applicable
Unit A
Non-volatile No
See also ANIN2MODE
ILIM
IMAX