Variables and Commands CDHD
394 VarCom Reference Manual
UVTIME
Definition Under-Voltage Time
Type Variable (R/W)
Description Gets/sets the amount of time that an under-voltage warning
will be displayed ("u") before it is latched in UVMODE 2.
In UVMODE 3, the time begins when the drive is enabled.
Syntax Read: UVTIME
Write: UVTIME <value>
Firmware 1.0.6
Drive status Enabled | Disabled
Range 0 to 300
Default value 30
Unit second
Non-volatile Yes
See also UVMODE
UVRECOVER
UVTHRESH
VBUS
VBUSREADOUT
CANopen 20D0h, sub-index 0