CDHD Variables and Commands
VarCom Reference Manual 147
IFFLPFHZ
Definition Current Feedforward Low Pass Filter
Type Variable (R/W)
Description Gets/sets the corner frequency of a first-order filter of the
feedforward low pass filter.
Syntax Read: IFFLPFHZ
Write: IFFLPFHZ <value>
Firmware 1.0.6
Drive status Enabled | Disabled
Range 10 to 1000
Default value 80 Hz
Unit Hz
Non-volatile Yes
See also KCBEMF
MKT
CANopen 2068h, sub-index 0