Variables and Commands CDHD
322 VarCom Reference Manual
PHASEFINDI
Definition Phase Find Current
Type Variable (R/W) .
Description Adjusts the current of the phase finding mechanism.
Syntax Read: PHASEFINDI
Write: PHASEFINDI <value>
Firmware 1.0.6
Drive status Disabled
Range 0 to 150
Default value 0
Unit A
Non-volatile Yes
See also PHASEFIND
PHASEFINDMODE
CANopen 20A7h, sub-index 0