CDHD Variables and Commands
VarCom Reference Manual 375
THERM
Definition Motor Over-Temperature
Type Variable (R)
Description The state of the motor thermostat input, which indicates
whether an over-temperature condition exists.
Syntax Read: THERM
Write: THERM <value>
Firmware 1.0.6
Drive status Enabled | Disabled
Range 0 = Thermostat input closed (normal) or ignored
(THERMODE 3).
1 = Thermostat input open, indicating overheating
Default value Not Applicable
Unit Not applicable
Non-volatile No
See also THERMODE
THERMREADOUT
THERMTRIPLEVEL
THERMCLEARLEVEL
THERMTIME
THERMTYPE
CANopen 20C4h, sub-index 0