EasyManua.ls Logo

Servotronix CDHD - Step

Servotronix CDHD
416 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CDHD Variables and Commands
VarCom Reference Manual 367
STEP
Definition Step Command
Type Command
Description Generates a step or square wave velocity command.
This command is similar to the J command, but allows
repetition of STEP to create a square wave velocity
command.
Syntax STEP {duration1} {velocity1} [duration2 velocity2]
Firmware 1.0.6
Drive status Disabled
Range Not Applicable
Default value Not Applicable
Unit Duration = ms
Velocity =
If MOTORTYPE 0 (Rotary):
If UNITSROTVEL 0 = rps
If UNITSROTVEL 1 = rpm
If UNITSROTVEL 2 = deg/s
If UNITSROTVEL 3 = user/s
If MOTORTYPE 2 (Linear):
UNITSLINVEL 1 = mm/s
UNITSLINVEL 2 = user/s
Non-volatile Not Applicable
See also ACC
J
OPMODE
RECORD
STOP
VLIM

Table of Contents

Other manuals for Servotronix CDHD

Related product manuals