Variables and Commands CDHD
84 VarCom Reference Manual
ESTMOTORPARAMST
Definition Motor Winding Estimation Procedure Status
Type Variable (R)
Description Reports the status of the ESTMOTORPARAM procedure.
Syntax ESTMOTORPARAMST
Firmware 1.3.2
Drive status Enabled | Disabled
Range Not Applicable; see Examples below
Default value Not Applicable; see Examples below
Unit Not Applicable; see Examples below
Non-volatile No
Example During execution:
-->estmotorparamst
Process Running
After a successful execution:
-->estmotorparamst
Process Done
MR = 2.172[Ohm], ML = 4.442[mH], DT = 10
Example When motor phases were disconnected just before execution
of ESTMOTOPARAM:
-->estmotorparamst
Process Done
MR = 0.137[Ohm], ML = 12.660[mH], DT = 318
DT (deadtime voltage) of 318 indicates that the motor is
not connected; it does not indicate a problem.
See also ESTMOTORPARAM