CDHD Variables and Commands
VarCom Reference Manual 227
MFOLDT
Definition Motor Foldback Time Constant
Type Variable (R/W)
Description Gets/sets the time constant for motor foldback.
After the drive enters the motor foldback state (MFOLD 1),
this variable defines how long it will take the drive to reduce
the system current level to MICONT.
Syntax Read: MFOLDT
Write: MFOLDT <value>
Firmware 1.0.6
Drive status Disabled
Range 1 to 1200
Default value 5.000
Unit second
Non-volatile Yes
See also MFOLDD
MFOLDDIS
MFOLDR
MICONT
MIPEAK
CANopen 2032h, sub-index 0