Variables and Commands CDHD
356 VarCom Reference Manual
SININITST
Definition Sine/Cosine Calibration Status
Type Variable (R)
Description Reports the status of the resolver calibration procedure.
Syntax SININIT
Firmware 1.0.6
Drive status Enabled | Disabled
Range 0 = Not started, or completed
1 = In progress
2 = Failed
Default value Not Applicable
Unit Not Applicable
Non-volatile No
See also FEEDBACKTYPE
HWPOS
RESBW
SINPARAM
SININITMODE
CANopen 20C0h, sub-index 0