Procedure
Figure5-24 Mounting option module OM-DQ in the option slot of the IP20 converter
Proceed as follows to mount option module OM-DQ in the option slot of the converter:
1. Remove the front cover (frame size FSA) or open the front door of the converter.
2. Open the front door of the converter.
3. Push option module OM-DQ up until it snaps in ush.
4. Tighten the xing screw with a T20 torx screwdriver, applying a torque of 2 Nm.
5. Press the cover caps onto the xing screws.
6. Place the front cover (frame size FSA) on the converter or close the front door of the
converter.
Result
Option module OM-DQ is connected to the converter.