15.2 Identication & Maintenance (I&M) data
Technical data
The converter supports the following identication and maintenance (I&M) data.
Table 15-3 I&M data
I&M data Format Explanation Example for the content
I&M0 unsigned8[54] PROFINET Converter-specic data, read only See below
I&M1 Visible String [32] Plant/system identier "ak12-ne.bo2=fu1"
Visible String [22] Location code "sc2+or45"
I&M2 Visible String [16] Date "2013-01-21 16:15"
I&M3 Visible String [54] Any comment or remark -
I&M4 Octet String[54] Check signature to track changes for Safety Inte‐
grated.
This value can be changed by the user.
Values of r9780[0],
r9781[0] and r9782[0]
When requested, the converter transfers its I&M data to a higher-level control or to a PC/PG
with installed STEP7 or TIAPortal.
Table 15-4 I&M0
Designation Format Example for the content
MANUFACTURER_ID unsigned16 2Ahex (=Siemens)
ORDER_ID Visible String [20] "6SL4113-0CA12-2AF0"
SERIAL_NUMBER Visible String [16] "T-R32015957"
HARDWARE_REVISION unsigned16 0001hex
SOFTWARE_REVISION char, unsigned8[3] "V" 06.10.00
REVISION_COUNTER unsigned16 0000hex
PROFILE_ID unsigned16 3A00hex
PROFILE_SPECIFIC_TYPE unsigned16 0000hex
IM_VERSION unsigned8[2] 01.01
IM_SUPPORTED unsigned16 001Ehex
System messages
15.2Identication & Maintenance (I&M) data
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 741