17.2.3 Biological environmental conditions
Technical data
Table 17-5 Resistance to biologically active substances
Usage phase Classication Description
Storage Class 1B1, according to IEC 60721-3-1:
1997
In the transport packaging
Transport Class 2B1, according to IEC 60721-3-2:
1997
In the transport packaging
Operation Class 3B1, according to IEC 60721-3-3:
2002
Mold, fungus, rodents, termites and other animal vermin are not
permissible.
17.2.4 Climatic conditions
Technical data
Table 17-6 Resistance to climatic conditions
Usage phase Classication Description
Storage Class 1K4 according to
IEC60721-3-1:1997
• In the transport packaging
• Temperature -25…+55°C
• Humidity 5...95%
• Storage altitude ≤ 4000m
• Condensation, splash water, icing, salt spray not permissible
Transport Class 2K4 according to
IEC60721-3-2:1997
• In the transport packaging
• Temperature -40…+70°C
• Humidity 5...95%
Operation Class 3K3 in accordance with IEC
60721-3-3 Ed. 2.2: 2002
• With increased ruggedness with respect to relative humidity
• Temperature -20…+60°C for IP20 degree of protection
• Temperature -20…+50°C for IP55 degree of protection
• Relative humidity 5 ... 95 % no condensation (better than Class
3K3)
• Ice formation, condensation, dripping water, spraying water,
splashing water and water jets are not permitted.
Technical data
17.2Environmental conditions
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 801