Parameters
The following list contains the parameters of the "Safe Motor Temperature (SMT)" function.
Number Name Unit
p9604.0...30 SI enable
14.12.7 Selection of the Safety Integrated Functions
Overview
The function selection oers the following setting options:
• Enable and inhibit each Safety Integrated Function
• Actual value acquisition and monitoring cycle
• Dening the axis type
Requirement
Certain Safety Integrated Functions require a license.
The SMT function requires the OM-SMT Option Module.
Description of function
Table 14-93 Safety Integrated Functions for every control type
Control type STO
1)
SS1
2)
SLS SSM SDI SMT
PROFIsafe x x x x x SMT is inde‐
pendent of
the control
type.
PROFIsafe and Emergency
Stop via terminals
x x x x x
Terminals x x x x x
The Safety Integrated Function requires the "Safety Extended" license.
1)
STO is enabled in the factory setting, and preassigned at failsafe digital input F-DI 0. When delivered, wire jumpers are inserted
at the F-DI 0. When using STO, remove the wire jumpers from F-DI 0 and connect an appropriate sensor (e.g. Emergency Stop
pushbutton). The wire jumpers remain inserted at the F-DI 0 if STO is not used.
2)
SS1-t does not require a license. SS1-a and SS1-r require a license.
Safety Integrated Functions are enabled with factory settings after function selection
(p9604).
The stop responses (STO and SS1) must always be parameterized because the stop responses
stop the motor in the event of an error and for a limit value violation. If the STO and SS1
functions are also to be controlled via PROFIsafe and/or F-DI, then STO and SS1 must also be
enabled.
Functions
14.12Safety Integrated
SINAMICS G220 converter
680 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB