14.9.7 Direction limiting
Overview
The "Direction limiting" function prevents the motor from rotating in the incorrect direction. This
can make sense for conveyor belts, extruders, pumps and fans, for example.
,QKLELW
GLUHFWLRQRI
URWDWLRQ
,QYHUW
6NLS
IUHTXHQF\
EDQGV
6HWSRLQWIRU
PRWRUFRQWURO
)URP
VHWSRLQW
VRXUFH
6SHHG
OLPLWDWLRQ
5DPSIXQFWLRQ
JHQHUDWRU
[
\
[
\
W
\\[[
Figure14-59 Setpoint processing in the converter
Description of function
Figure14-60 Direction limiting in the extended setpoint channel
Both directions of rotation of the motor are enabled in the factory setting of the converter.
Parameters
The following list contains the parameters of the "Direction limiting" function.
Number Name Unit
c1110[0...n] Inhibit negative direction
c1111[0...n] Inhibit positive direction
Functions