7.1.4.2 Access to the power connections up to frame size FSC
Precondition
The housing cover has been removed.
Tool required: Torx screwdriver T20
Procedure
Proceed as follows to access the converter power connections up to frame size FSC:
59
59
Figure7-6 Establishing access to the power connections
1. Release the two screws marked in the diagram.
2. Slide the sheet metal plate marked in the diagram upwards until the lower side of the sheet-
metal edge engages with the catch.
Proceed as follows after connecting the power cables:
/N
/N
Figure7-7 Sliding down the sheet metal plate and tightening the screws