c0840[0...n] ON / OFF (OFF1)
p1001[0...n] Fixed speed setpoint 1 [rpm]
p1002[0...n] Fixed speed setpoint 2 [rpm]
p1003[0...n] Fixed speed setpoint 3 [rpm]
p1004[0...n] Fixed speed setpoint 4 [rpm]
p1016 Fixed speed setpoint select mode
c1020[0...n] Fixed speed setpoint selection bit 0
c1021[0...n] Fixed speed setpoint selection bit 1
c1022[0...n] Fixed speed setpoint selection bit 2
c1023[0...n] Fixed speed setpoint selection bit 3
r1024 Fixed speed setpoint eective [rpm]
c1070[0...n] Main setpoint
c2103[0...n] 1st acknowledge faults
14.8.1.2 I/O presetting "Fieldbus with data set switchover"
Overview
In order to avoid having to successively change terminal by terminal, multiple terminals can be
set jointly with one operating unit.
With the I/O preset "Fieldbus with data set switchover", the converter is prepared for
operation on the eldbus.
Requirement
The preset can only be changed using the Startdrive commissioning tool or the web server.
The preset is only useful if a eldbus telegram has been congured.
Description
The I/O preset "Fieldbus with data set switchover" is the factory setting of the converter with
PROFINET interface.
The converter obtains its signals via the eldbus. With 1 signal at digital input DI3, the motor
can be traversed via the digital inputs DI0 and DI1.
Functions
14.8Inputs/outputs
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 419