r0031 Actual torque smoothed [Nm]
p1082[0...n] Maximum speed [rpm]
p2181[0...n] Load monitoring response
p2182[0...n] Load monitoring speed threshold value 1 [rpm]
p2183[0...n] Load monitoring speed threshold value 2 [rpm]
p2184[0...n] Load monitoring speed threshold value 3 [rpm]
p2185[0...n] Load monitoring torque threshold 1 upper [Nm]
p2186[0...n] Load monitoring torque threshold 1 lower [Nm]
p2187[0...n] Load monitoring torque threshold 2 upper [Nm]
p2188[0...n] Load monitoring torque threshold 2 lower [Nm]
p2189[0...n] Load monitoring torque threshold 3 upper [Nm]
p2190[0...n] Load monitoring torque threshold 3 lower [Nm]
p2191[0...n] Load monitoring torque threshold no load [Nm]
p2192[0...n] Load monitoring delay time [s]
p2193[0...n] Load monitoring conguration
14.11.16.5 Load monitoring failure detection
Overview
The "Load monitoring failure detection" function evaluates a periodic binary signal. A missing
signal indicates that the motor and the load are no longer mechanically coupled.
Description of function
The converter monitors the speed or velocity of a machine component using an
electromechanical or electronic sensor, e.g. a proximity switch.
The converter evaluates whether the sensor periodically delivers a 24 V signal during motor
operation. If the sensor signal is missing for time p2192, the converter signals fault F07936.
%*Y
'
D
5
SY
Q
'
U
U
7
%*Y
Q
Figure14-203 Function diagram and time response of the load monitoring failure detection
Example
Examples of how the function can be used:
• Gearbox monitoring for traction drives or hoisting gear
• Drive belt monitoring for fans or conveyor belts
• Blocking protection for pumps or conveyor belts
Functions
14.11Drive functions
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 621