• "Limit values"
The converter limit values are shown graphically and in a tabular form.
The limit values must be congured on an application-specic basis.
• "I/O conguration"
The function view oers the following conguration options:
Conguration Description
Dierent assignment of command data sets 0
and 1
–
Assign functions to digital inputs/digital outputs
and analog inputs/analog outputs
–
Select I/O presets Changes to the precongured I/O presets are dis‐
played with the prex [changed].
10.5.1.3 Optimization
Overview
Optimization proceeds once quick setup is complete.
The optimization settings are preset and cannot be adjusted during quick setup. It is possible
to congure desired settings as part of advanced setup.
Requirement
You have connected the motor.
Description of function
The optimization process includes motor data identication with stationary motor and starts the
next time the motor is switched on.
10.5.1.4 Advanced setup
Overview
With the advanced setup, you dene drive options and functions to suit your application. The
advanced setup contains all settings of the quick setup, plus additional options and functions.
Commissioning (web server)