14.10.4.6 Resonance damping
Overview
Resonance damping reduces speed oscillations for a motor without load or for sudden load
changes.
Description of function
With p1349>0, resonance damping is active for the following output frequencies:
Between 6% and 90% of the motor rated frequency f
MotN
Maximum 45Hz
With p1349=0, resonance damping is active for the following output frequencies:
95% of the motor rated frequency f
MotN
Maximum 45Hz
IBRXWSXW
,TBDFW
8IUHVGDPS7
8IUHVGDPSJDLQ
XIUHVGDPS
S
U
S
yS
U
II
0RW1
S
Figure14-114 Resonance damping
Parameters
The following list contains the parameters of the "Resonance damping" function.
Number Name Unit
r0066 Output frequency [Hz]
r0078[0...1] Current actual value torque-generating [Arms]
p0310[0...n] Rated motor frequency [Hz]
p1338[0...n] U/f mode resonance damping gain
p1339[0...n] U/f mode resonance damping 󹪝lter time constant [ms]
p1349[0...n] U/f mode resonance damping maximum frequency [Hz]
Functions