EasyManua.ls Logo

Siemens SINAMICS G220 - Compound Braking

Siemens SINAMICS G220
834 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14.11.9 Compound braking
Overview
The converter uses compound braking to brake the load along a de󹪝ned ramp-down ramp
without the need for a braking resistor or a converter with energy recovery.
Requirement
Suitable for applications in which the motor must be braked electrically but neither a converter
with energy recovery nor a braking resistor is available.
Typical applications are:
Centrifuges
Saws
Grinding machines
Horizontal conveyors
Applications involving suspended loads, e.g. hoisting gear/cranes or vertical conveyors, are
not permitted.
The compound braking function is not possible for a power failure.
Additional requirements:
Compound braking is only possible with U/f control.
The "Flying restart" function is deactivated.
DC braking is deactivated.
NOTICE
Overheating of the motor due to compound braking
Compound braking can subject the motor to thermal overload. A thermal overload damages
the motor.
Monitor the motor temperature.
Allow the motor to cool down between braking operations.
Functions
14.11Drive functions
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 601

Table of Contents