4. Establish an online connection between Startdrive and the target device
5. Make basic settings online via the guided quick startup in editing mode
Make basic settings in quick startup screen forms
Perform optimization
Result:
The motor rotates.
More information
Detailed information can be found in the information system of the TIA Portal in Chapter
"Con󹪝guring SINAMICS G220 drives".
11.3.4 Basic parameterization together with a SIMATIC controller
Procedure
If you want to commission the SINAMICS drive together with a SIMATIC control system, the
optimum sequence for basic parameterization is as follows:
1. Create or open the project with Startdrive
2. Create the device con󹪝guration in Startdrive o󹪠ine
Insert the SINAMICS drive into the project and specify it
Create and specify SINAMICS components and make detailed settings
Insert the SIMATIC controller into the project and specify it
Network the SIMATIC controller and drive
Optional: Con󹪝gure user administration and make protection settings for the drive and
control
Insert a technology object into the SIMATIC controller
Interconnect the technology object with the drive
3. Download project data to the target devices
4. Establish an online connection between Startdrive and the target device
5. Make basic settings online via the guided quick startup in editing mode
Make basic settings in quick startup screen forms
Perform optimization
Result:
The motor rotates.
Commissioning (Startdrive)
11.3Device con󹪝guration and basic parameterization
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 285