Siemens SINAMICS G220 - Setting of Technological Application for Closed-Loop Speed Control

Siemens SINAMICS G220
834 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
I
q
and I
d
controllers keep the motor 󹪞ux constant using the output voltage, and adjust the
matching current component I
q
in the motor.
Parameters
The following list contains the parameters of the "Closed-loop speed control" function.
Number Name Unit
p0230 Drive 󹪝lter type motor side
p0235 Motor reactor in series number
p0342[0...n] Ratio between the total and motor moment of inertia
p0350[0...n] Motor stator resistance cold [ohm]
p0352[0...n] Cable resistance [ohm]
p1441[0...n] Actual speed smoothing time [ms]
p1442[0...n] Speed controller speed actual value smoothing time [ms]
p1452[0...n] Speed controller speed actual value smoothing time
(sensorless)
[ms]
p1460[0...n] Speed controller P gain
p1462[0...n] Speed controller integral time [ms]
p1470[0...n] Speed controller encoderless operation P gain
p1472[0...n] Speed controller encoderless operation integral time [ms]
p1496[0...n] Acceleration precontrol scaling [%]
p1610[0...n] Starting torque static (without encoder) [%]
p1750[0...n].0...9 Motor model con󹪝guration
14.10.5.2 Setting of technological application for closed-loop speed control
Overview
Parameter p0500 optimizes the open-loop and closed-loop control parameters for speed
control.
Requirement
A license is required for the speed-controlled operation of reluctance motors at low speeds using
the pulse technique.
Functions
14.10Closed-loop drive control
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 509