17.2 Environmental conditions
17.2.1 Mechanical environmental conditions
Technical data
Table 17-2 Resistance to mechanical environmental conditions
Usage phase Classi󹪝cation Description
Storage Class 1M2 according to
IEC60721-3-1:1997
In the transport packaging
Transport Class 2M3 according to
IEC60721-3-2:1997
In the transport packaging
Operation Class 3M1according to
IEC60721-3-3:2002
Vibration test according to IEC60068-2-6test Fc (sinusoidal)
9...29Hz: Amplitude: 0.3mm
29...200Hz: Acceleration: 1g
10frequency cycles per direction
Shock test according to IEC60068-2-27test Ea (half-sine)
Peak acceleration: 5g
Duration: 30ms
3 shocks per direction
Table 17-3 Resistance to mechanically active substances
Usage phase Classi󹪝cation Description
Operation Class 3S1 according to IEC 60721-3-3:
Ed. 2.2: 2002
Conductive dusts are not permitted.
17.2.2 Chemical environmental conditions
Technical data
Table 17-4 Resistance to chemically active substances
Usage phase Classi󹪝cation Description
Storage Class 1C2, according to IEC 60721-3-1:
1997
In the transport packaging
Transport Class 2C2 according to
IEC60721-3-2:1997
In the transport packaging
Operation Class 3C2 according to IEC 60721-3-3:
2002
Technical data