14.11.1.2 Motor control with ON/reverse commands
Overview
The command "ON/OFF1" starts and stops the motor. The "Reverse" command reverses the
direction of rotation of the motor.
Description of function
$MPDLXJTFSPUBUJPO
$PVOUFSDMPDLXJTFSPUBUJPO
0/0''
3FWFSTF
U
4QFFETFUQPJOU
45014501
Figure14-167 Two-wire control, ON/reverse
Table 14-81 Function table
ON/OFF1 Reverse Function
0 0 The motor stops.
The converter brakes the motor to a standstill.
0 1
1 0 The motor starts.
The converter accelerates the motor in the "clockwise" direction.
1 1 The motor starts.
The converter accelerates the motor in the "counter-clockwise" di‐
rection.
Parameters
The following list contains the parameters of the "Motor control with ON/reverse commands"
function.
Number Name Unit
r0722.0...22 Digital inputs status
c0840[0...n] ON / OFF (OFF1)
c1113[0...n] Setpoint inversion
Functions
14.11Drive functions
SINAMICS G220 converter
570 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB

Table of Contents