EasyManua.ls Logo

Siemens SINAMICS G220 - Inputs and Outputs

Siemens SINAMICS G220
834 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17.10 Inputs and outputs
Technical data
Table 17-20 Technical data of inputs and outputs
Property Data
24 V supply There are 2 options for the 24 V supply:
Internal power supply
The converter generates its 24 V power supply internally from the line voltage.
Contact-safe SELV power supply via terminal strip X124 with 20.4V-28.8V DC
Maximum current consumed: 3A
The supply voltage must not exceed 60V in the event of a fault.
Voltages in excess of 60V will permanently damage the converter.
Output voltages
24V
Maximum output current 200mA
10V ± 0.5V
Maximum output current 10mA
Digital input Type 3 according to IEC61131-2
Isolated using an optocoupler
Maximum permissible input voltage 30V
Input voltage for "low" state: <5V
Input voltage for state "high">11V
Current for state "high" 2.5... 4.0mA
Response time 0.25ms
Rapid input
DI5
Pulse frequency when used as pulse train input 32kHz
Response time when used as measuring probe input 0.01ms
Analog input Di󹪜erential input
16-bit resolution
Response time 4ms
Overvoltage protection up to ±35V
Operating mode selection:
0V...10V or -10V...10V: Input resistance 100kΩ, maximum voltage35V
0mA...20mA, 4mA...20mA: Input resistance 120Ω, maximum voltage8V, maximum
current65mA
Digital output/relay output Transistor output DO0: Reverse polarity protection
Relay outputs DO1 and DO2
Response time 3ms
30V DC / ≤0.5A for a resistive load