Table 6-13 Dimensions, line voltage 3 AC380...500V
Article number Unit Width Height Depth
6SL3201-0BE14-3AA0 mm 105 295 100
6SL3201-0BE21-0AA0 mm 105 345 100
6SL3201-0BE21-8AA0 mm 175 345 100
6SL3201-0BE23-8AA0 mm 250 490 140
JJY:023422620001 mm 220 180 470
JJY:023424020001 mm 220 180 610
JJY:023434020001 mm 630 350 630
JJY:023454020001
1)
JJY:023422620001 ∥
JJY:023434020001
mm
mm
220
630
180
350
470
630
JJY:023464020001
1)
JJY:023434020001 ∥
JJY:023434020001
mm
mm
630
630
350
350
630
630
1)
The article number contains two braking resistors, which are connected in parallel.
6.2.4 Minimum clearances, braking resistor in degree of protection IP21
Requirement
CAUTION
Risk of burns and damage from hot surface
The braking resistor surface can assume temperatures exceeding 100°C.
Touching the hot surface may result in burns. The hot surface may damage or destroy
temperature-sensitive parts.
Ensure that no temperature-sensitive parts come into contact with a hot surface.
Mount the braking resistor so that it is not accessible in operation.
Measures when maintenance is required:
Allow the braking resistor to cool down before starting any work.
Use appropriate personnel protection equipment, e.g. gloves.
Mounting
6.2Braking resistor
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 143