6.2 Braking resistor
6.2.1 Mounting position
Requirement
NOTICE
Overheating due to impermissible mounting position
The braking resistor can overheat and therefore be damaged if mounted in an impermissible
position.
• Only mount the braking resistor in a permissible position.
Description
Mounting in a horizontal position or in a vertical position with the connections at the bottom
is permissible.
Mounting with the connections at the top or mounted on a ceiling is not permissible.
6.2.2 Weight, braking resistor in degree of protection IP21
Technical data
Table 6-10 Weight, line voltage 3 AC200...240V
Braking resistor
Article number Unit Weight
JJY:023151720007 kg 0.7
JJY:023163720018 kg 1.1
JJY:023433720001 kg 2.0
JJY:023422620002 kg 7.0
JJY:023423320001 kg 8.5
Mounting
6.2Braking resistor
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 141