EasyManua.ls Logo

Siemens SINAMICS G220 - Control Panel

Siemens SINAMICS G220
834 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
10.5.8 Control panel
Overview
The control panel moves the motor using the operating unit, bypassing the higher-level
controller, for example to test the converter settings after commissioning.
Requirement
WARNING
Unexpected motor movement through incorrect operation
If the control panel is active, the safety shutdowns of the higher-level controller have no
e󹪜ect. The "Stop with space bar" function is not guaranteed in all operating states. Incorrect
operation by untrained personnel may result in unexpected motor movement which can cause
death or serious injuries.
Only use the control panel for commissioning, diagnostics and service purposes.
Only use the control panel if you are trained and authorized accordingly.
Install an EMERGENCY STOP for the drive which is independent of the higher-level controller.
Description of function
Figure10-25 Control panel
The "Take over control" dialog deactivates the signals of the higher-level controller and
switches the source for enables and the setpoint value to the control panel.
Note
Drive responds immediately
Although all enable signals are removed before returning the master control, the setpoints and
commands still come from the original parameterized sources after the master control is
returned.
Commissioning (web server)
10.5Functions and menus
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 273

Table of Contents

Related product manuals