11.2.7 Using parameter lists and user-dened lists
Overview
Users congure a drive in Startdrive as standard using specic conguration views. For the
conguration, experienced users preferably take the parameter lists or user-dened lists.
Requirement
• For activated user management (UMAC):
The function rights for editing drive data are activated for your user account.
Details on this topic are provided in the Conguration Manual SINAMICS Industrial Security
(
https://support.industry.siemens.com/cs/ww/en/view/109810578) in Chapter "Security
settings in Startdrive".
Parameter list
The following functions are available:
• Monitoring parameter values
• Editing parameter values directly from the parameter view
Only parameters with a light grey background can be directly edited in the parameter list.
Other parameters are locked in the parameter list and cannot be edited.
• Exporting parameters as CSV
• Comparing parameter settings:
– Oine - Factory setting
– Online - Oine
– Online - Factory setting
User-dened list
You compile the selected parameters in a user-dened list. This involves an excerpt with specic
parameters, from an underlying parameter list.
User-dened lists are only created and edited in the project tree.
You use user-dened lists for the following purposes:
• Compiling the most important parameters
• Assigning parameters to parameter groups with comments for users
• Carrying out series commissioning based on saved parameter values
• Documentation of the drive with listed parameters and setting values
Opening and reading parameter lists in the web server
Parameter lists are exported in the json format. You can import and open lists and view
parameter values if you access the converter using the web server.
Commissioning (Startdrive)
11.2Basics
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 281