14.4.10.6 Error values
Overview
The converter responds to invalid PROFIenergy commands with an error value.
Description of function
Table 14-18 Error value in the parameter response
Error val‐
ue1
Meaning
01 hex Invalid ID service request
03 hex Invalid modier
04 hex Invalid ID request data structure
06 hex No energy-saving mode supported
07 hex Response too long
08 hex Impermissible block header
50 hex No suitable energy saving mode on the converter for the selected pause duration
51 hex The scheduled pause time is too short for the converter to switch to a pause mode.
52 hex Invalid mode ID
53 hex The converter cannot enter an energy-saving mode because it is in operation.
54 hex Function currently not available
56 hex No UMAC write access
57 hex No UMAC read access
Functions
14.4PROFINET communication
SINAMICS G220 converter
384 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB