Table 14-50 Explanation of attribute ID 5 of the previous table
Byte Bit Name Description
1 0 Assignment 0:Converter is not assigned to a controller
1:Converter is assigned to a controller
1 ‑ Reserved
2 Conguration 0:Ethernet/IP basic settings
1:modied Ethernet/IP settings
3 ‑ Reserved
4…7 Extended device
status
0:Self-test or status not known
1:Firmware update active
2:At least one I/O connection with error
3:No I/O connections
4:Incorrect conguration in the ROM
5:Fatal fault
6:At least one I/O connection is active
7: All I/O connections in the quiescent state
8 … 15: Reserved
2 8…11 ‑ not used
12…15 ‑ Reserved
14.6.4.2 "Connection management object" class
Overview
The "connection management object" enables communication diagnostics.
Description of function
The "connection management object" has object class 06hex.
Table 14-51 Class attributes
Attrib‐
ute ID
Service
1)
Type Name
1 get UINT16 Revision
2 get UINT16 Maximum instance
3 get UINT16 Number of instances
1)
Supported services: Get attribute single, get attribute all
Table 14-52 Instance attributes
Attrib‐
ute ID
Service
1)
Type Name Value/explanation
1 get UINT16 Open Requests Counters
2 get UINT16 Open Format Rejects Counters
3 get UINT16 Open Resource Rejects Counters
Functions
14.6Ethernet/IP communication
SINAMICS G220 converter
404 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB