17.9 Power loss
17.9.1 3 AC 200 ... 240 V, degree of protection IP20
Technical data
Table 17-16 Absolute power loss in W at operating point (90/100)
1)
Article number Rated power IEC NEC
6SL4112-...☐☐-..F0 @ 230V, 50Hz @ 240V, 60Hz
05 0.55kW 66.9 58.1
06 0.75kW 78.6 71.5
08 1.1kW 107 98.6
10 1.5kW 144 112
11 2.2kW 191 166
12 3kW 202 174
13 4kW 277 213
15 5.5kW 373 296
16 7.5kW 498 392
17 11kW 566 511
18 15kW 842 694
20 18.5kW 1061 935
21 22kW 1154 1002
23 30kW 1527 1391
1)
The operating point (90/100) means: relative motor stator frequency 90%, relative torque current 100%
Power loss was measured at a pulse frequency of 4kHz and with space-vector modulation.
17.9.2 3 AC 380 V … 415 V / 3 AC 440 V … 500 V, degree of protection IP20
Technical data
Table 17-17 Absolute power loss in W at operating point (90/100)
1)
Article number Rated power IEC NEC
6SL4113-...☐☐-..
F0
@ 400V, 50Hz @ 480V, 60Hz
Un󹪝ltered Filtered Un󹪝ltered Filtered
08 1.1kW 77.2 78.3 72.2 72.8
10 1.5kW 90.6 92.2 77.3 78.1
11 2.2kW 123 126 103 104
Technical data
17.9Power loss
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 815