All available unit groups and possible unit selections are listed below.
Table 14-86 Unit groups (p0100)
Unit group Unit selection for p0100= Reference value for%
0, 2 1
7_4 Nm lbf ft -
8_4 N lbf -
14_2 W W -
14_6 kW HP -
14_13 W/A HP/A -
14_14 W min/1000 HP min/1000 -
14_15 W/A
2
HP/A
2
-
14_16 W min
2
/1000
2
HP min
2
/1000
2
-
25_1 kgm
2
lb ft
2
-
27_1 kg lb -
28_1 Nm/A lbf ft/A -
29_1 N/Arms lbf/Arms -
30_1 m ft -
47_1 kW s/K HP s/K -
48_1 W/K HP/K -
48_2 W min/1000 K HP min/1000 K -
48_3 W min
2
/1000
2
K HP min
2
/1000
2
K -
50_1 K/W K/HP -
14.11.3.2 Reference values
Overview
There is a reference value in the converter for most parameters with a physical unit.
Description of function
When the per-unit representation [%] is set, the converter scales the physical quantities based
on the respective reference value.
If the reference value is changed, the signicance of the scaled values also changes. Example:
• Reference speed = 1500rpm → xed speed=80% corresponds to speed = 1200rpm
• Reference speed = 3000rpm → xed speed=80% corresponds to speed = 2400rpm
The parameter list provides the associated reference value for the scaling for each parameter.
For example, r0065 is scaled with reference value p2000.
If no scaling is specied in the parameter list, the converter always expresses the parameter
unscaled.
Functions
14.11Drive functions
SINAMICS G220 converter
578 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB