11.2.2 Protected communication
Description
If the Startdrive project and the converter are unprotected, access is possible via both interfaces.
This enables unrestricted access from the project or a higher-level controller to the drive data.
Non-authorized users can manipulate the drive data. To avoid the risk of data manipulation,
we recommend protecting access to the project and the converter.
Detailed information about security settings is provided in the Conguration
Manual SINAMICS Industrial Security (
https://support.industry.siemens.com/cs/ww/en/view/
109810578).
11.2.3 Loading data from the drive into the project
Overview
If you change the conguration of a converter in the online mode, then the conguration
deviates from the data in the Startdrive project. To update project data, load the drive data from
the converter into the project.
Requirement
• A project with a matching drive is created and is open in Startdrive.
• The converter and SIMATICS7 controller are in oine mode.
• For activated user management (UMAC) in Startdrive:
The function rights for editing drive data and the hardware conguration are activated for
your user account.
You also need the function right "Edit Safety Integrated application of the drive" for editing
Safety Integrated data.
• For activated user management (UMAC) in the converter:
The "Create backup or load drive data to Startdrive" function right is activated for your user
account.
Details on this topic are provided in the Conguration Manual SINAMICS Industrial Security
(
https://support.industry.siemens.com/cs/ww/en/view/109810578) in section "Security
settings in Startdrive".
Commissioning (Startdrive)
11.2Basics
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 277