Enter the drive password that was used to encrypt the drive data in the backup 󹪝le.
The converter takes the drive data from the backup 󹪝le.
The settings at the time of the backup are restored.
Function "Drive data encryption" is activated.
The originally con󹪝gured drive password is applied.
10.5.5.6 Restore factory settings
Overview
The "Restore factory settings" function deletes the user-speci󹪝c parameterization of the
converter, for example the motor data.
The following data remains in the converter:
Communication interface settings
Security settings including UMAC data
Language setting
Date and time
In the following cases it may be necessary to restore the converter to factory settings:
Di󹪜erence in topology when replacing a motor with/without DRIVE-CLiQ interface
Uncertainty regarding the previous parameterization or the previous use of the converter
Requirement
Requirements:
Before carrying out a reset, save the drive data in a backup 󹪝le so that you can access the
settings again.
Rights required for active user management (UMAC):
"Edit device con󹪝guration or drive applications"
If Safety Integrated is contained in the backup 󹪝le, the "Edit Safety Integrated application"
right is required.
Procedure
Proceed as follows to reset the drive settings to the factory settings:
1. Call the "Backup and restore" menu.
2. Press the "Restore factory settings" button.
3. Acknowledge the con󹪝rmation prompt.
4. The converter resets its drive settings to the factory settings.
Commissioning (web server)
10.5Functions and menus
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 261