6.1.5 Installation, converter in degree of protection IP20
Description
The converter is intended to be mounted on a rear control cabinet panel.
Table 6-3 Rear view of the converter and mounting parts, frame sizes FSA … FSC, IP20
FSA FSB FSC
Rear view of the
converter
All dimensions
in mm
¡







¡





¡
Mounting parts 4 × M4 screws
4 × M4 washers
4 × M5 screws
4 × M5 washers
4 × M5 screws
4 × M5 washers
Tightening tor‐
que
6Nm 6Nm 6Nm
Mounting
6.1Converter
SINAMICS G220 converter
134 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB