14.11.5 Data sets
14.11.5.1 Switching between di󹪜erent drive con󹪝gurations
Overview
A drive con󹪝guration may require di󹪜erent converter settings, depending on the application.
The settings are stored in drive data sets.
Description of function
%SJWFGVODUJPOT
0QFOMPPQDPOUSPMPS
DMPTFEMPPQDPOUSPM
'JFMECVT
DPNNVOJDBUJPO
*OQVUTPVUQVUT
4BGFUZ*OUFHSBUFE
4FUQPJOUDIBOOFM
5FDIOPMPHZ
GVODUJPOT
Figure14-174 Con󹪝guration settings with drive data sets
The parameters for drive con󹪝gurations are indexed. A setting of the function can be stored
for each index. One of the four indices can be selected using control commands.
The settings in the converter with the same index are called a drive data set (DDS). The
converter can switch between the di󹪜erent drive data sets .
Functions
14.11Drive functions
SINAMICS G220 converter
580 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB