Figure14-33 I/O preset "Fieldbus with data set switchover"
Table 14-64 Signal interconnection of the inputs and outputs
Input Signal interconnection Output Signal interconnection
DI0
DI1
DI2
DI3
c1055[1] = r0722.0
c1056[1]=r0722.1
c2103[1]=r0722.2
c0810[0]=r0722.3
DO0
DO1
c0730 = r0052.3
c0731 = r0052.2
AO 0 c0771[0] = r0021
Parameters
The following list contains the parameters of function "I/O presetting Fieldbus with data set
switchover".
Number Name Unit
r0722.0...22 Digital inputs status
c0730 Signal for terminal DO 0
c0731 Signal for terminal DO 1
c0771[0] Analog output signal
c0810 Command data set selection CDS bit 0
c1055[0...n] Jog bit 0
c1056[0...n] Jog bit 1
c2103[0...n] 1st acknowledge faults
Functions
14.8Inputs/outputs
SINAMICS G220 converter
420 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB