- 2460 -
1
PROFIdrive
MELDW status word interconnection
© Siemens AG
2 3 4 5 6 7 8
V6.02.00
MELDW.0
MELDW.1
MELDW.2
MELDW.3
MELDW.4
MELDW.5
MELDW.6
MELDW.8
MELDW.9
MELDW.11
MELDW.12
MELDW.13
MELDW.14
MELDW.7
MELDW.10
c2053[4].2 = r2199.0
c2053[4].3 = r2197.1
c2053[4].7 = r2135.7
c2053[4].8 = r2199.4
-
-
c2053[4].11 = r0899.8
c2053[4].12 = r0899.7
c2053[4].0 = r2199.5
c2053[4].1 = r2199.11
[2537.7]
[2534.7]
[2526.7]
-
[2549.7]
[2549.7]
[2537.7]
-
-
[2503.7]
[2537.7]
[2537.7]
[8021]
[8011]
-
-
[2610]
[2610]
Signal
<1>
MELDW.15
Interconnection
parameter
Meaning
[Function diagram]
signal target
[Function diagram]
internal control word
1 = Drive ready
Reserved
1 = Speed setpoint - actual value deviation within tolerance t_on
1 = Controller enable
1 = No alarm, thermal overload, power unit
Reserved
1 = No motor overtemperature alarm
Variable signaling function 1 output signal
1 = Vdc_min controller active
1 = |n_act| > speed threshold value 2 (p2155)
1 = |n_act| < speed threshold value 3 (p2161)
1 = Torque utilization < torque threshold value 2 (p2194)
1 = Ramp-up/ramp-down completed
<2> The MELDW is generated using c2053[4].0...15.
c2053[4].4 = r0056.15
c2053[4].5 = r3294.0
c2053[4].6 = r2135.6
[8011]
[8012]
[8010]
[8010]
[6220], [6320]
[8024]
[8016]
c2053[4].15 = r3294.2Variable signaling function 3 output signal
1 = Pulses enabled
Variable signaling function 2 output signal
c2053[4].13 = r0899.11
c2053[4].14 = r3294.1
[2503.7]
-
[2610]
[8024]
Signal sources for MELDW
- [8024]
[2503.7]
<2>
<1> Used in telegram 102, 103.
Figure14-18 2460‑MELDW status word interconnection
Functions
14.4PROFINET communication
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 357