Table 14-66 Eective setpoint
c1020 c1021 c1022 c1023 r1024
0 0 0 0 0
1 0 0 0 p1001
0 1 0 0 p1002
1 1 0 0 p1001 + p1002
0 0 1 0 p1003
1 0 1 0 p1001 + p1003
0 1 1 0 p1002 + p1003
1 1 1 0 p1001 + p1002 + p1003
0 0 0 1 p1004
1 0 0 1 p1001 + p1004
0 1 0 1 p1002 + p1004
1 1 0 1 p1001 + p1002 + p1004
0 0 1 1 p1003 + p1004
1 0 1 1 p1001 + p1003 + p1004
0 1 1 1 p1002 + p1003 + p1004
1 1 1 1 p1001 + p1002 + p1003 + p1004
Binary mode
The binary mode is recommended to select xed speed setpoints using a higher-level control
system.
In the binary mode, up to 16 dierent xed speed setpoints p1001 ... p1015 are dened. A
certain combination of selection bits is assigned to each of the 16 xed speed setpoints.
'JYFETQFFETFUQPJOUTFMFDUJPOCJU
'JYFETQFFETFUQPJOUTFMFDUJPOCJU
'JYFETQFFETFUQPJOUTFMFDUJPOCJU
'JYFETQFFETFUQPJOUTFMFDUJPOCJU
'JYFETQFFETFUQPJOU
'JYFETQFFETFUQPJOU
'JYFETQFFETFUQPJOUFFDUJWF
'JYFETQFFETFUQPJOU
'JYFETQFFETFUQPJOU
'JYFETQFFETFUQPJOU
S
D
D
D
D
Q
Q
Q
Q
Q
Figure14-54 Binary selection of xed speed setpoints
Table 14-67 Eective setpoint
c1020 c1021 c1022 c1023 r1024
0 0 0 0 0
1 0 0 0 p1001
0 1 0 0 p1002
Functions
14.9Setpoint channel
SINAMICS G220 converter