- 3051 -
1
Setpoint channel
Speed limitations
© Siemens AG
2 3 4 5 6 7 8
V6.02.00
<1>
Max
-1
Min
1
r1112
Speed setpoint after minimum limiting [rpm]
r1119
Ramp-function generator setpoint at the input [rpm]
r1087
Negative speed limit effective [rpm]
r1084
Positive speed limit effective [rpm]
c1051 [C]
(1083[0])
Speed limit RFG positive direction of rotation
c1052 [C]
(1086[0])
Speed limit RFG negative direction of rotation
c1088 [C]
(1086[0])
Speed limit in negative direction of rotation
Maximum speed
0.000 ... 210000.000 [rpm]
p1082 [D] (1500.000)
<1>
Speed limit in positive direction of rotation
0.000 ... 210000.000 [rpm]
p1083 [D] (40000.000)
Speed limit in negative direction of rotation
-210000.000 ... 0.000 [rpm]
p1086 [D] (-40000.000)
c1085 [C]
(1083[0])
Speed limit in positive direction of rotation
Limiting to negative
values
Reference value for the ramp function generator
Maximum limiting active
0
0
0
0
[3060.1]
[3070.1]
[6031.1]
[8022.1]
[6030.1]
[6640.5]
[8010.2]
[3080.5]
[3020.5]
[3060.4]
[3070.4]
[6030.1]
[6640.5]
[8010.2]
Value of p1082 is limited to maximum motor speed (p0322).
[3050.8]
Figure14-68 3051 - Speed limitations
Functions
14.9Setpoint channel
SINAMICS G220 converter
Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB 455