Description of function
Unlike the extended ramp-function generator, the basic ramp-function generator does not use
rounding times.
5DPSXSWLPH5DPSGRZQ
WLPH
0D[LPXP
VSHHG
\
W
[
[\
W
[
[
Figure14-72 Basic ramp-function generator in the extended setpoint channel
Parameters
The following list contains the parameters of the "Basic ramp-function generator" function.
Number Name Unit
p1082[0...n] Maximum speed [rpm]
p1115 Ramp-function generator selection
p1120[0...n] Ramp-function generator ramp-up time [s]
p1121[0...n] Ramp-function generator ramp-down time [s]
p1135[0...n] OFF3 ramp-down time [s]
Functions
14.9Setpoint channel
SINAMICS G220 converter