EasyManua.ls Logo

Siemens SINAMICS G220 - Page 488

Siemens SINAMICS G220
834 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 6836 -
1
Dynamic Drive Control (DDC, p0504 = 2)
Id setpoint (Permanent-magnet synchronous motor, p0300 = 2xxx)
© Siemens AG
2 3 4 5 6 7 8
V6.02.00
1
0
M
Iq
Iq
M
[6832.8]
[6839.8]
Field weakening
precontrol characteristic
[6843.4]
1 = Controlled operation
r1751.0
[6842.4]
Kt Rel
Lq
Ld
Motor stator leakage inductance
0.00000 ... 1000.00000 [mH]
p0356 [M] (0.00000)
Motor stator inductance d axis
0.00000 ... 1000.00000 [mH]
p0357 [M] (0.00000)
Motor reluctance torque constant
-1000.00 ... 1000.00 [mH]
p0328 [M] (0.00)
P
K
Id
+
0.9 · r0067
[6842.4]
Starting torque static (without encoder)
-200.0 ... 200.0 [%]
p1610 [D] (50.0)
Acceleration starting torque (encoderless)
0.0 ... 200.0 [%]
p1611 [D] (30.0)
Ramp-function
generator operating
Calculation
absolute current
+
r0094
Transformation angle [°]
r0077
Current setpoint torque-
generating [Arms]
Closed-loop
operation
Open-loop
operation
← →
[6842.4]
<1>
r0079
Torque setpoint [Nm]
Current setpoint smoothing time
4 ... 10000 [ms]
p1616 [D] (40)
Current injection ramp time
1 ... 10000 [ms]
p1601 [D] (20)
Optimum motor load angle
0.0 ... 135.0 [°]
p0327 [M] (90.0)
Actual motor magnetizing current/short-circuit current [Arms]
r0331 [M]
-1
+
[6829.1]
[6833.1]
r1593[0..1]
Field weakening controller /
flux controller output [Arms]
[6839.8]
Open-loop
operation
Switchover
<1>
Effective injection ramp time:
p1601: When switching over from open-loop controlled to closed-loop controlled operation
p1616: When switching over from closed-loop controlled to open-loop controlled operation
Setting value field-
generating current
+
MTPA characteristic field-
generating current setpoint
[6829.5]
[6832.1]
[6799.5]
M
[6824.3]
Torque setting value
speed controller
Motor model kT adaptation corrective value [Nm/A]
r1797 [D]
Field-generating current setpoint total [Arms]
r1624
Figure14-97 6836 - Id setpoint (permanent-magnet synchronous motor)
Functions
14.10Closed-loop drive control
SINAMICS G220 converter
486 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB

Table of Contents

Related product manuals