• Line impedance
• Actual motor torque
The maximum possible output voltage as a function of the input voltage is provided in the
technical data.
The converter has dierent U/f characteristics.
6
TFU
4FMFDUJPOPGUIF
DIBSBDUFSJTUJD
*OEFQFOEFOUWPMUBHF
TFUQPJOU
&$0NPEF
G
TFU
*
R@TFU
.BYJNVNPVUQVU
WPMUBHF
3BUFENPUPSGSFRVFODZ
-JOFBS
1BSBCPMJD
1SPHSBNNBCMF
'$$
Q
Q
S
Q
S
S
Q
S
① The voltage boost of the characteristics improves speed control at low speeds
② When the ux current control (FCC) is used, the converter compensates for the voltage drop in the
stator resistance of the motor
③ In the ECO mode, the converter optimizes the motor eciency in steady-state operation. The
optimization is only eective when the ramp-function generator is not bypassed.
④ For settings 5 and 6, the converter keeps the output frequency constant:
• Slip compensation is inhibited
• When reaching the current limit, the I_max controller only reduces the motor voltage but not
the output frequency.
Figure14-105 Characteristics of U/f control
Functions
14.10Closed-loop drive control
SINAMICS G220 converter
494 Operating Instructions, 04/2024, FW V6.2, A5E51781573B AB